Plan QA with IQM (German)
Author: Sonja Wegener, et al, Unversity Clinic Wurzburg (Germany) Summary: Clinical experience using IQM for VMAT Plan QA.
Plan QA with IQM (German) Read More »
Author: Sonja Wegener, et al, Unversity Clinic Wurzburg (Germany) Summary: Clinical experience using IQM for VMAT Plan QA.
Plan QA with IQM (German) Read More »
Author: Oluwaseyi M. Oderinde, et al, University of the Free State, Bloemfontein (South Africa) Summary: Assess the dose variation sensitivity of two quality assurance (QA) devices (IQM and MatriXXEvolution)
Sensitivity evaluation of two QA system to organ-dose variation of VMAT plans Read More »
Author: Gary Razinskas, et al, Unversity Clinic Wurzburg (Germany) Summary: This article verifies the accuracy of the signal prediction for the Synergy Agility MLC. Tolerance criteria for VMAT plan verification with the IQM were obtained from the observed sensitivity for the detection of incorrectly delivered plans. This study used 60 VMAT plans to compare the
Sensitivity of the IQM to errors of VMAT plans Read More »
Author: Masahide Saito, et al, University of Yamanachi (Japan) Summary: This article compares the MLC error sensitivity of various measurement devices for VMAT pre‐treatment quality assurance (QA).
Comparison of MLC error sensitivity of various QA systems for VMAT Plan QA Read More »
Author: Livia Marrazzo, et al, Multi-centre study of 3 RT departments Summary: This article shows the ability of detecting small delivery errors with a transmission detector for online monitoring of Intensity Modulated Radiation Therapy (IMRT) treatments. The authors also show how the IQM signal deviations strongly correlate with changes in the dose-volume-histogram for the PTV
Real-time beam monitoring for error detection in IMRT plans and impact on DVH Read More »
Author: Marlies Pasler, Livia Marrazzo, et al, Lake Constance Radiation Oncology Center, Friedrichshafen (Germany) and University of Florence (Italy) Summary: Deviations in dose distributions between the original and error-induced plans were compared in terms of detector signal deviation, dose-volume histogram (DVH) metrics and 2D γ-evaluation.
Error detection capability of IQM: an validation study for online VMAT monitoring Read More »
Author: Makan Farrokhkish, et al, Princess Margaret Cancer Centre, Toronto (Canada) Summary: Evaluation of the IQM beam monitoring performance to assess the accuracy and reproducibility of the linac beam delivery. The signal calculation accuracy and measurement reproducibility as well as the error detection capability of the IQM System was evaluated. For this study the author
Real-time verification of VMAT delivery Read More »
Author: Kilian Michel, Lake Constance Radiation Oncology Center, Singen-Friedrichshafen (Germany) Summary: Sensitivity of PTW Octavius, IBA Dolphin and IQM for various delivery errors
Correlation of error detection sensitivities for two VMAT QA systems Read More »
Author: Sonja Wegener, et al, Unversity Clinic Wurzburg (Germany) Summary: Evaluation of the IQM System for IMRT plan QA. The IQM Calculation algorithm has been validated for a wide spectrum of clinical IMRT cases. The error sensitivity of the IQM System has been tested with a variety of induced errors. The error detection capability of
IMRT Plan QA with IQM Read More »
Author: Kilian Michel, Lake Constance Radiation Oncology Center, Singen-Friedrichshafen (Germany) Summary: Evaluation of the IQM System for Online Dosimetry during the patient treatment. The long-term signal stability, the error detection sensitivity for induced errors, the correlation of the IQM and the Dose-Volume-Histogram as well as treatment plan verification with the IQM System has been evaluated.
Online Dosimetry with IQM Read More »