Publications
The IQM System has been thoroughly evaluated by some of the world's leading radiation therapy centers.
Select your topic of interest from 15 articles, 19 posters,
19 presentations and 3 technical white papers.
Sensitivity Analysis of the IQM System using Monte Carlo Simulation
Author:
Oluwaseyi M. Oderinde, et al, University of the Free State, Bloemfontein (South Africa)
Summary:
Evaluation of the IQM error sensitivity in beam segments using EGSnrc/BEAMnrc Monte Carlo (MC) codes
Response characteristics of the IQM
Author:
Makan Farrokhkish, Princess Margaret Cancer Centre, Toronto (Canada)
Summary:
Evaluation of the intrinsic and effective spatial sensitivity, response as a function of field size, beam energy and dose rates
Online quality assurance of external beam radiation therapy
Author:
David Hoffman, UC Comprehensive Cancer Center, Sacramento (USA)
Summary:
Evaluation of the stability and accuracy of each IQM system feature.
Efficient and enhanced QA testing of Linear Accelerators using IQM
Author:
Andrew Jongho Jung, Princess Margaret Cancer Centre, Toronto (Canada)
Summary:
Investigating the use of IQM for various Machine QA applications: beam output, beam symmetry, relative dose factor, MLC calibration, output as function of dose rate, dose linearity and output as function of gantry angles
Initial evaluation of the IQM
Author:
Bruce Perrin, et al, Christie Hospital, Manchester (UK)
Summary:
The authors validated the effectiveness and reliability of the IQM to monitor the correct delivery of daily fractions.
Pre-clinical test of the IQM System
Author:
Stefania Pallotta, AOU Careggi, Florence (Italy)
Summary:
The author states that IQM provides an optimal performance for IMRT QA. Intra-fractional %STD of 0.04% and inter-fractional %STD of up to 0.36% for complex IMRT cases over a period of multiple weeks are the results of this study.
White Paper: IQM Detector characteristics: Signal reproducibility
Author:
iRT Systems, Koblenz (Germany)
Summary:
Investigation of the signal reproducibility of the IQM System
White Paper: IQM Detector characteristics: Signal linearity and dose rate dependence
Author:
iRT Systems, Koblenz (Germany)
Summary:
Investigation of the signal linearity and dose rate dependence of IQM System
An IQM System for real-time verification of IMRT
Author:
Mohammad Islam, et al, Princess Margaret Cancer Centre, Toronto (Canada)
Summary:
The proof of concept publication (2009) for the IQM system